C1, TM 11-6625-646-15
d. If no further tests are to be performed stop the
a. Turn the SAS amplifier selector switch to DC,
test set (para 4-20).
then to AC. Observe the SAS amplifier meter for the
required indication.
4-19. Calibration Card
b. Set the AXES METERS READ switch to
Test a calibration card as follows:
CLOSED LOOP.
c. Turn the SAS amplifier selector switch, inturn, to
NOTE
PITCH, ROLL, S/SLIP, and YAW.  At each switch
The CALIBRATION TEST POINTS
position, operate the L-R switch to each position.
connect to the corresponding pins of
Observe the SAS amplifier meter for the required
the
CALIBRATION
CARD
test
indication.
receptacle.
Since the calibration
card does not include complete
4-15. Printed-Wiring Circuit Board (Card) Tests
functioning circuits, testing is limited
to
and
4-16.  To test a SAS amplifier card, perform the
measurements.
preliminary procedures (para 4-4).  Then proceed as
directed below.
a. Plug the card into the CALIBRATION test
receptacle component-side down.
4-17. Demodulator-Modulator Card
Test a demodulator-modulator card as follows:
b. Refer to the SAS amplifier schematic diagram
for circuit points and component values.  Calibration
a. Plug the card into the DEM/MOD CARD TES
card circuit configurations and component values are
TER receptacle, component-side down.
Turn the
not the same for all SAS amplifier models.
FUNCTION switch to DEM OUPT, Set the 115V 400~
POWER switch to on (up) position.
c. Adjust  the  multimeter  to  the  appropriate
resistance range or adjust the C-I-R bridge to the
b. Adjust variable resistor R76 on the card until the
appropriate capacitance range. Connect the test leads
FUNCTION meter indicates 0.
to the CALIBRATION TEST POINTS to be measured.
c. Set the CARD TEST SIGNAL switch to L.
Observe the FUNCTION meter for the required
indication.
NOTE
The test of the ASE function of the
d. Set the CARD TEST SIGNAL switch to R.
calibration card is not applicable to
Observe the FUNCTION meter for the required
indication.
the CH-47 SAS amplifiers.
d. Remove the card from the test receptacle.
e. If no further tests are to be performed, stop the
test set (para 4-20).
e. If any measurements are not correct, repair or
install a new card as necessary.
4-18. Amplifier Card
f. Stop the test set (para 4-20).
Test an amplifier card as follows:
a. Turn the FUNCTION switch to AMPL OUPT.
4-20. Stopping Procedure
Plug the card into the AMPLIFIER CARD TESTER
receptacle, component-side down.  Set the 115V 400
4-21. Stop the test set as follows:
POWER switch to on (up) position.
a. Set the 115V 400~POWER switch to off (down)
b. Set the CARD TEST SIGNAL switch to L.
position.
Observe the FUNCTION meter for the required
b. Disconnect all test and power cables from the
indication.
test set.
c. Set the CARD TEST SIGNAL switch to R.
c. Stow all cables and the adapter in the cover of
Observe the FUNCTION meter for the required
the test set.
indication.
d. Close the hinged door.  Secure it with the
turnlock fasteners.
33