Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

C1, TM 11-6625-646-15
NOTE
c. Set the 115V 400 ~ POWER switch to on (up)
The AXIS meters will indicate off-
position.  Check that the FULL GAIN indicator lamp
comes on. Check that the FUNCTION meter indicates
scale and slowly return to center-
in the green.
scale. This is normal and does not
indicate equipment malfunction.
Table 4-1. Controls
Control
Function
FUNCTION Switch S7 (1) ................................. Four-pole, 11-position rotary switch; selects circuit to be tested and
connects this circuit to the FUNCTION meter to measure voltages.
The color of the dot at each switch position indicates the sector of
the meter scale where voltage should be indicated. Where two dots
appear, the position of the CARD TEST SIGNAL switch determines
the sector where voltage should be indicated. The function of each
switch position is as follows:
DC-measures the level of the dc operating voltage to the SAS am-
plifier.
AC-measures the level of ac operating voltage to the SAS amplifier.
YAW FEED BACK POT. EXCITATION-measures the level of
the excitation voltage for the primary feedback variable resistor
in the yaw extensible link.
ROLL FEED BACK POT. EXCITATION-measures the level of
the excitation voltage for the primary feedback variable resistor
in the roll extensible link.
PITCH FEED BACK POT. EXCITATION-measures the level of
the excitation voltage for the primary feedback variable resistor
on the pitch extensible link.
SEC FEED BACK POT. EXCITATION-measures the level of the
excitation voltage for the secondary variable resistors on the
pitch, roll, and yaw extensible links.
PEDAL POT. EXCITATION measures the level of excitation volt-
age to the pedal position variable resistor.
INTLK-measures the level of the dc interlock voltage to the other
SAS amplifier.
DEM OUPT-measures the output of the demodulator-modulator
card when the card is plugged into the DEM/MOD CARD TEST-
ER receptacle of the test set and the CARD TEST SIGNAL
switch is operated.
AMPL OUPT-measures the output of the amplifier card when the
card is plugged into the AMPLIFIER CARD TESTER receptacle
of the test set and the CARD TEST SIGNAL switch is operated.
PEDAL POT. OUPT-measures the simulated feedback output of
the PEDAL POT variable resistor.
CARD TEST SIGNAL Switch S6 (3) ................. Single-pole double-throw toggle switch with two momentary positions;
connects the test signal to the input of the demodulator-modulator
or amplifier card that is connected to the CARD TESTER receptacle
of the test set. Color of dot indicates the sector of the FUNCTION
meter where voltage should be indicated.
PEDAL POT Variable Resistor R502 (5) ........... No function on CH-47 SAS amplifiers.
HALF GAIN Switch S3 (8)
Normally open push-button switch; when depressed, it energizes the
gain control relay in the SAS amplifier causing the amplifier to
operate at half gain.
ASE MODE Switch S8 (12) .
No function on CH-47 SAS amplifiers.
115V 400~ POWER Switch S1 (13).................. Three-ampere circuit breaker switch; connects and protects the 115-
volt 400-cycle ac circuit to the test set.