Click here to make tpub.com your Home Page

Page Title: Table 6-2. Test Set Checkout Procedure
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-6625-3023-14/ET904-AA/MMA-010/E154 TS3684/TO 33A1-12-1173-1
Table 6-2. Test Set Checkout Procedure
Test instructions
Normal indication
NOTE
Test point location
1.
Resistance measurements
CAUTION
Disconnect test set
from AC power before
making resistance
measurements.
a.
Using a digital multimeter
40 ohms +10%
(see Maintenance Allocation
Chart, appendix D) set to
the RX100 scale, connect
meter leads to test points
A and B (AC plug). Switch
S1 to ON position.
b.
Connect leads of DVM to points
280 ohms +20%
C and D (circuit board).
c.
Connect positive lead to test
Greater than 300K ohms
point C, common lead to GRD.
Switch S5 to SHORT position.
Set DVM to RX1OK scale.
d.
Connect common lead to test
Less than 100 ohms
point C, positive lead to GRD.
Switch S5 to SHORT position.
Set DVM to RX1 scale.
e.
Connect positive lead to test
Greater than 300K ohms
point E, common lead to GRD.
Switch S5 to SHORT position.
Set DVM to RX1OK scale.
f.
Connect common lead to test
Less than 5K ohms
point E, positive lead to GRD.
Switch S5 to SHORT position.
Set DVM to RX100 scale.
g.
Connect positive lead to test
Greater than 300K ohms
point F, common lead to GRD.
Switch S5 to SHORT position.
Set DVM to RX1OK scale.
6-10

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business