CHAPTER 4
ORGANIZATIONAL MAINTENANCE INSTRUCTIONS
Section I. GENERAL INFORMATION, AND TROUBLESHOOTING
AND REFINISHING INSTRUCTIONS
further corrosion. Refer to the applicable cleaning and
4-1.
Repair Parts, Special Tools, Special Test
refinishing practices specified in TB 43-0118.
Equipment and Accessories
Items
required
for
performing
organizational
4-3. Troubleshooting Procedures
maintenance are listed in the Maintenance Allocation
Chart, Appendix D of this manual and in the Repair Parts
Troubleshooting the TS-3630 is based on the operational
and Special Tools List, TM 11-5895-1097-20P.
check contained in the preventive maintenance charts.
When an abnormal indication is observed, refer to
troubleshooting  chart.
Perform  the  checks  and
4-2. Painting
corrective measures  indicated.
If  the corrective
Remove rust and corrosion from metal surfaces by lightly
measures indicated do not result in correction of the
sanding them with fine sandpaper. Brush two thin coats
trouble, higher category maintenance is required.
of paint on the bare metal to protect it from
Item
Check and
No.
Trouble Symptom
Probable Trouble
Corrective Measure
a. POWER ON indicator defective.
a. Replace lamp (para 4-4).
1
POWER ON indicator does not light.
b. Line fuse defective.
b. Replace fuse (para 4-5).
c. Powerline cable defective.
c. Check attachment of wires to
plug terminals; insure that
they are plugged into source.
d. No line voltage.
d. Check voltage at outlet
2
NO GO indicator does not light with
switch in LAMP TEST position.
NO GO indicator defective.
Replace lamp (para 4-4).
3
GO indicator does not light with switch
in LAMP TEST position.
GO indicator defective.
Replace lamp (para 4-4).
4
Indicator lenses cracked or broken.
Replace with new lens (para 4-6).
d. Replace the cap; press in and turn clockwise to lock.
Section II. MAINTENANCE OF TEST SET, CRYSTAL
4-6. Replacement of Indicator Lamp Lenses
MODULE TS-3630/GRA-114
a. Turn the indicator lamp lens counterclockwise
and remove from its socket.
4-4. Replacement of POWER ON, NO GO and GO
b. Replace by screwing clockwise into the socket.
Indicators
a. Turn the lens cover counterclockwise and remove
4-7. Replacement of Pressure Relief Valve
it to expose defective lamp.
a. Remove control panel from case.
b. Grasp lamps and pull straight out.
b. Remove defective pressure relief valve.
c.  Replace lamp with a new one by pushing the
c. Replace new valve.
lamp into socket.
d. Replace control panel in case.
d. Replace the lens cover by turning clockwise.
4-5. Replacement of Fuse
a. Press the fuseholder cap in and turn it counter-
clockwise.
b. Pull the cap out; this will withdraw the fuse from
c. Remove the fuse from the cap and replace it with
a new one.