5.26.6.
ACTR POSN Simulator
d. Rotate LATL ACCRM L/R control fully
CW. multimeter shall indicate -3.96 6 0.41 vdc.
Performance Check.
5.26.8.2. Adjustments. Adjustments can not be
a.
Connect multimeter to ACTR POSN SIM
made.
No. 1 and to NO. 1 SIG GND.
YAW RATE Simulator.
b.
Place ACTR POSN mode selector control
to SIM STAB 1 & 2..
Performance Check.
c.
Rotate ACTR POSN DN/UP control fully
a.
Connect multimeter toYAW RATE SIM
CCW. Multimeter shall indicate -13.5 6 1.5 vdc.
and SAS SIG REF YAW.
d.
Rotate ACTR POSN DN/UP control fully
b.
Place AIRSPEED SWITCH mode selector
CW. Multimeter shall indicate 13.5 6 1.5 vdc.
control to ,60 KNOTS.
Adjustments. Adjustments can not be
c.
Rotate YAW RATE L/R control fully
made.
CCW. Multimeter shall indicate -1.3 6 0.3 vdc.
PITCH RATE GYRO Simulator.
d.
Rotate YAW RATE L/R control fully CW.
Multimeter shall indicate 1.3 6 0.3 vdc.
Performance Check.
e.
Disconnect multimeter from test set.
a.
Connect multimeter to PITCH RATE
GYRO SIM STAB 1 and NO. 1 SIG GND.
Adjustments. Adjustments can not be
made.
b.
Place PITCH RATE GYRO mode selector
control to SIM STAB 1 &2.
ROLL ATT Mechanical Zero.
c.
Rotate PITCH RATE GYRO NOSE
DN/NOSE UP fully CCW. multimeter shall indicate
Performance Check.
5.17 6 0.53 vdc.
a.
Line up ROLL ATT coarse control (inner
d.
Rotate PITCH RATE GYRO NOSE
dial) 909 marking with index mark; ROLL ATT fine
DN/NOSE UP fully CW. multimeter shall indicate
control (outer dial) 909 marking shall also align with
-5.17 6 0.53 vdc.
index mark and 909 coarse marking. If fine control
909 marking does not align, go to paragraph
5.26.7.2.
Adjustments. Adjustments can not be
made.
b.
Line up ROLL ATT coarse control (inner
LATL ACCRM Simulator.
dial) 91809 marking with index mark; ROLL ATT
fine control (outer dial) 909 marking shall also align
Performance Check.
with index mark and 91809 coarse marking. If fine
control 909 marking does not align, go to paragraph
a. Connect multimeter to LATL ACCRM SIM
STAB 1 and NO. 1 SIG GND.
Adjustments.
b. Place LATL ACCRM mode selector control
to SIM STAB 1 &2.
a.
While holding coarse control so it doesn't
move, align 909 marrking on fine control (outer dial)
c. Rotate LATL ACCRM L/R control fully
CCW. multimeter shall indicate 3.96 6 0.41 vdc.
with index mark and tighten setscrews.