Click here to make tpub.com your Home Page

Page Title: TABLE NO. 3-28. INDICATORS NO. 2 SLEW DN And NO. 2 HOT SLEW Do Not Go On When MANUAL SLEW 2 Switch Is Pressed And Held At DN.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 1-6625-735-14
TABLE NO. 3-28. INDICATORS NO. 2 SLEW DN And NO. 2 HOT SLEW Do Not Go On When
MANUAL SLEW 2 Switch Is Pressed And Held At DN.
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Test lamps for condition before continuing.
During the following steps, note the status
(on or off) of all lamps.
1. Press and hold MANUAL SLEW 2 control to DN. INDICATORS NO. 2 SLEW DN
and NO. 2 HOT SLEW shall light.
Step 1. If indicator lamps do not go on, go to 2.
Step 2. If indicator lamps go on, go to 3.
2. Check switch S9 for continuity.
Step 1. If continuity exists, replace component board assembly A3.
Step 2. If continuity does not exist, replace switch S9.
3. Release MANUAL SLEW 2 control. INDICATORS NO. 2 SLEW DN and NO. 2
HOT SLEW shall go off. Go to 4.
4. If indicator lamps do not go off, replace switch S9.
TABLE NO. 3-29. INDICATORS NO. 1 RESET And NO. 2 RESET Do Not Go On When RESET
Switch Is Pressed And Held.
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Test lamps for condition before continuing.
During the following steps, note the status
(on or off) of all lamps.
1. Press and hold RESET control. INDICATORS NO. 1 RESET and NO. 2 RESET
shall light.
Step 1. If indicator lamps do not go on, go to 2.
3-26