Click here to make tpub.com your Home Page

Page Title: Table 3-13. Multimeter Does Not Indicate 2.3 6 0.1 Vdc With AS SENSOR Switch Placed To SIM STAB 2 Or To SIM STAB 1
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 1-6625-735-14
Multimeter Does Not Indicate 2.3 6 0.1 Vdc With AS SENSOR Switch Placed To
TABLE NO. 3-13.
SIM STAB 2 Or To SIM STAB 1. (Cont)
TEST OR INSPECTION
CORRECTIVE ACTION
3. Check switch S2 for continuity.
Step 1. If continuity exists, replace circuit board assembly A2.
Step 2. If continuity does not exist, replace switch S2.
4. Connect multimeter between AS SENSOR SIM NO. 2 and SIG GND test jacks.
Go to 5.
5. Place AS SENSOR control to SIM STAB 1. Multimeter shall indicate 2.3 6 0.1 vdc.
Go to 6.
6. If multimeter indicates 0.0 vdc, replace switch S2.
TABLE NO. 3-14. Multimeter Does Not Indicate 0 6 0.15 Vdc When AS SENSOR Control Is Turned
Fully Counterclockwise And Does Not Indicate 12.2 6 1.25 Vdc When AS SENSOR Control Is Turned
Fully Clockwise.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Place AS SENSOR control to SIM STAB 1&2. Go to 2.
2. Connect multimeter between AS SENSOR SIM NO. 1 and SIG GND test jacks.
Go to 3.
3. Turn AS SENSOR control throughout its range from fully counterclockwise (DECR)
to fully clockwise (INCR). Multimeter shall indicate 0 6 0.15 vdc when AS SENSOR
control is fully counterclockwise and shall indicate 12.2 6 1.25 vdc when AS SENSOR
control is fully clockwise. Multimeter shall indicate a continuously adjustable voltage
from counter-clockwise to clockwise position.
Step 1. If multimeter indicates 0.0 vdc, go to 4.
Step 2. If multimeter indication is not correct, replace component board assembly A4.
Step 3. If multimeter indication changes abruptly from -0.15 to 13.45 vdc, replace
potentiometer R2.
4. Check switch S2 for continuity.
Step 1. If continuity exists, replace circuit board assembly A2.
Step 2. If continuity does not exist, replace switch S2.