TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
CAUTION
The synchro transmitter control is a precision instrument that contains a slip
clutch and an 18 to 1 reduction mechanism between the outer (fine) dial and
the inner (coarse) dial. Use care to avoid over torquing this mechanism which
will result in activation of the slip clutch and loss of calibration between inner
and outer dials. Always use outer dial when adjusting to a specific degrees
setting. If it is necessary to use inner dial, MAKE SURE to turn dial using a
slow, smooth, continuous motion.
Mode Selector Control
NORM position supplies three-wire roll signal output of No. 2 vertical gyro
through test set connector J3 to SAS amplifier. This signal can be monitored at
X, Y, and Z SIM test points. SIM 1 supplies variable three-phase ac simulation
signal selected by synchro transmitter control through test set connector J3 to
SAS amplifier. This simulation signal can be monitored at X, Y, and Z SIM
test points. SIM 2 jumpers DC ROLL ATT and ROLL RATE TESTtest points
together and supplies variable three-phase ac simulation signal selected by syn-
chro transmitter control through test set connector J3 to SAS amplifier. This
simulation signal can be monitored at X, Y, and Z SIM test points.
TEST POINTS
Provide monitoring capability for functional conditions of SAS system opera-
tion.
P VALVE HI/LO Test
Provide monitoring capability for resistance and voltage measurements of pitch
Points
SAS valve in pitch/trim assembly.
R VALVE HI/LO Test
Provide monitoring capability for resistance and voltage measurements of roll
Points
SAS valve, in roll actuator.
Y VALVE HI/LO Test
Provide monitoring capability for resistance and voltage measurements of yaw
Points
SAS valve, in yaw boost servo.
Provides monitoring capability for amplified SAS amplifier yaw
TURN RATE COIL
MH-60K
rate gyro output.
HI/LO Test Points
DC ROLL ATT Test
Provides monitoring capability for transformed roll attitude from SAS ampli-
Point
fier. Three-wire simulation signal is supplied by test set ROLL ATT simulator
to SAS amplifier. SAS amplifier changes three-wire ac to two-wire dc. Ampli-
tude of dc (transformed roll attitude) is directly proportional to amount of
degrees of roll attitude displacement simulated by ROLL ATT simulator.
When ROLL ATT simulator mode selector control is placed to SIM 2, DC
ROLL ATT test point is connected to ROLL RATE TESTtest point.
ROLL RATE TEST Test
Provides monitoring capability for simulated SAS amplifier
MH-60K
Point
derived rate signal. When test set ROLL ATT simulator mode selector control
is placed to SIM 2, ROLL RATE TEST test point is connected to DC ROLL
ATT test point.
ROLL RATE Test Point
Provides monitoring capability for SAS amplifier derived rate sig-
MH-60K
nal.
2-27