TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
FAULT MONITOR I
NORM enables No. 2 stabilator amplifier current limit fault monitor circuit to
LIMIT 2 Control
function normally if a current sense fault exists. INHIBIT supplies ground
through test set connector J2 to No. 2 stabilator amplifier, preventing shutdown
of No. 2 stabilator automatic mode, should a current sense fault exist.
TEST position supplies 28 vdc to No. 1 pitch rate gyro to provide
RATE GYRO TEST
MH-60K
gyro self-test operation.
PITCH 1 Control
RATE GYRO TEST
TEST position supplies 28 vdc to No. 2 pitch rate gyro to provide
MH-60K
PITCH 2 Control
gyro self-test operation.
RATE GYRO TEST
TEST position supplies 28 vdc to roll rate gyro to provide
MH-60K
ROLL Control
gyro self-test operation.
TEST position supplies 28 vdc to yaw rate gyro to provide gyro
RATE GYRO TEST
MH-60K
self-test operation.
YAW Control
PITCH 1 TEST
Provides monitoring capability for No. 1 pitch rate gyro 28 vdc
MH-60K
MONITOR Test Point
self-test signal.
PITCH 2 TEST
Provides monitoring capability for No. 2 pitch rate gyro 28 vdc
MH-60K
MONITOR Test Point
self-test signal.
ROLL TEST MONITOR
Provides monitoring capability for roll rate gyro 28 vdc self-test
MH-60K
Test Point
signal.
YAW TEST MONITOR
Provides monitoring capability for yaw rate gyro 28 vdc self-test
MH-60K
Test Point
signal.
SELF TEST ENABLE
Provides monitoring capability for rate gyro self-test enable signal
MH-60K
Test Point
from AFCS control panel.
TEST POINTS
Provide monitoring capability for functional conditions of stabilator system
operation. NO. 1 test points relate to No. 1 stabilator amplifier, and NO. 2 test
points relate to No. 2 stabilator amplifier.
NO. 1 and NO. 2 UP
Provide monitoring capability for No. 1 and No. 2 stabilator amplifiers scaling
CMD and NO. 1 and NO.
amplifier gated output command signal. Command signal determines which
2 DN CMD Test Points
drive in driver logic module turns on to command actuator. Each test point
voltage may be 15 vdc or 0 vdc.
NO. 1 and NO. 2 STAB
Provide monitoring capability for voltages supplied by No. 1 and No. 2 stabila-
UP and NO. 1 and NO. 2
tor amplifiers that will drive No. 1 and No. 2 stabilator actuators. When system
STAB DN Test Points
is in manual slew mode, test points have steady 28 vdc. When system is in
automatic mode, test points have 0 vdc to 28 vdc pulse with modulation.
NO. 1 and NO. 2 AUTO
Provide monitoring capability for 28 vdc engage voltage supplied by No. 1 and
ENGA Test Points
No. 2 stabilator amplifiers as soon as power is applied to helicopter, or when
stabilator is operated in automatic mode. NO. 1 and NO. 2 AUTO ENGA and
NO. 1 and NO. 2 AUTO ENGA OS indicators also go on.
NO. 1 and NO. 2 DRVR
Provide monitoring capability for 28 vdc from No. 1 and No. 2 stabilator
SPLY Test Points
amplifier that will be supplied back to drive amplifiers in No. 1 and No. 2 sta-
bilator amplifiers. 28 vdc is available at these test points as soon as power is
applied to helicopter or when stabilator is operated in automatic mode. NO. 1
and NO. 2 DRVR SPLY and NO. 1 and NO. 2 DRVR SPLY OS indicators
also go on.
2-22