Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
STAB 1 SNSR Test Point
Provides monitoring capability for signal output of pitch rate gyro in No. 1
stabilator amplifier. When mode selector control is at NORM, STAB 1 SNSR
test point is connected to STAB 1 SIM test point.
STAB 1 SIM Test Point
Provides monitoring capability for No. 1 stabilator amplifier-pitch rate gyro
simulation signal when mode selector control is at SIM STAB 1 & 2 or SIM
STAB 1. Provides monitoring capability for ground supplied to No. 1 stabilator
amplifier-pitch rate path when mode selector control is at GND, SIM STAB 2,
SIM SAS 1, or SIM SAS (WO). When mode selector control is at NORM,
STAB 1 SIM test point is connected to STAB 1 SNSR test point to provide
monitoring capability for signal output of pitch rate gyro in No. 1 stabilator
amplifier.
STAB 2 SNSR Test Point
Provides monitoring capability for signal output of pitch rate gyro in No. 2
stabilator amplifier. When mode selector control is at NORM, STAB 1 SNSR
test point is connected to STAB 1 SIM test point.
STAB 2 SIM Test Point
Provides monitoring capability for No. 2 stabilator amplifier-pitch rate gyro
simulation signal when mode selector control is at SIM STAB 1 & 2 or SIM
STAB 2. Provides monitoring capability for ground supplied to No. 2 stabilator
amplifier-pitch rate path when mode selector control is at GND, SIM STAB 1,
SIM SAS 1, or SIM SAS (WO). When mode selector control is at NORM,
STAB 2 SIM test point is connected to STAB 2 SNSR test point to provide
monitoring capability for signal output of pitch rate gyro in No. 2 stabilator
amplifier.
SAS SNSR Test Point
Provides monitoring capability for No. 1 stabilator amplifier-filtered pitch rate
output signal. When mode selector control is at NORM or STAB 1, SAS
SNSR test point is connected to SAS SIM test point.
SAS SIM Test Point
Provides monitoring capability for No. 1 stabilator amplifier-filtered pitch rate
simulation signal when mode selector control is at SIM SAS 1 or SIM SAS
(WO). Provides monitoring capability for ground supplied to SAS amplifier
when mode selector control is at GND, SIM STAB 1 & 2, and SIM STAB 2.
When mode selector switch is at NORM or SIM STAB 1, SAS SIM test point
is connected to SAS SNSR test point to provide monitoring capability for No.
1 stabilator amplifier-filtered pitch rate output signal.
2-18